DF-GEN-01-TP-02 / DRAFT-1
Supported cover and cartridge-path rehearsal
Inspect the rigid model relationships and supported path; this is not an operating instruction.
CONCEPT TRAINING PROCEDURE DRAFT
Read the boundary before the steps.
Inert model/approved training fixture only. Not an OEM operating SOP, service release or competence certificate.
Configuration: DF-GEN-01 / DEMO-01 · Review status: concept draft, responsible acceptance owner to be assigned.
INERT MODEL EXERCISE
Steps, expected observations and model links.
-
01
HOUSING
Begin with identification
Complete the configuration/component exercise and state the inert-model boundary.
Expected observation: Correct fixture and source revision are identified.
Inspect this component and pose ↗ -
02
DOOR
Inspect access
Open the model access-door view. Check the door/fixture relationship visually.
Expected observation: Door clears the represented support path.
Inspect this component and pose ↗ -
03
CLIP_UPPER
Inspect the upper pivot
Select the upper retaining assembly and observe that its pivot stays on the fixed structure.
Expected observation: The upper assembly is conserved.
Inspect this component and pose ↗ -
04
CLIP_LOWER
Inspect the lower pivot
Select the separate lower assembly; the cover remains seated until both represented states have been reviewed.
Expected observation: Two assemblies remain; housing is fixed.
Inspect this component and pose ↗ -
05
COVER
Inspect supported separation
Move to the axial cover-inspection pose. The support carriage follows the cover.
Expected observation: Cover motion is axial and continuously supported.
Inspect this component and pose ↗ -
06
COVER_SUPPORT
Inspect the clear position
View the cover’s supported rightward inspection position.
Expected observation: The cartridge axis is clear before A moves.
Inspect this component and pose ↗ -
07
CRADLE
Inspect the cradle
Observe the lowered extension and subsequent raised support pose.
Expected observation: Support is in place before A is shown withdrawn.
Inspect this component and pose ↗ -
08
ELEMENT_A
Inspect the same A
Move toward full inspection spread and follow A along the same axis.
Expected observation: The original A stays rigid; B does not move into the housing.
Inspect this component and pose ↗ -
09
ELEMENT_A
Inspect the reverse path
Return the inspection slider toward assembly: A returns before supports retract and the door closes.
Expected observation: The inverse order is visible; no new cartridge appears.
Inspect this component and pose ↗ -
10
HOUSING
Close the exercise record
Record unclear geometry or evidence for a qualified reviewer. Physical fit and release need their own approved source.
Expected observation: Model inspection is not recorded as real equipment readiness.
Inspect this component and pose ↗
NEXT REVIEW